Show 

Test Record


E2B Import

 

For each occurrence of this entity, an AER_LAB record will be created.

 

Refer the "MedDRA Mapping - Import" for more details.

 

E2B Export

 

For this entity the information will be taken from AER_LAB table.

 

Check the value present in the AER_LAB. TEST_NAME_LLT_CODE/PT_CODE/TEST_NAME based on the "Test Name Coding" and "MedDRA Coding" selection, if it is not a valid MedDRA code or decode, then populate the B.3.2 resultstestprocedures with the concatenated Field information from B.3.X fields. In this case, current ARISg Mapping will be used to retrieve the field values. AER.laboratory_description will be concatenated with the B.3.X field information. B.3 containing testname and other fields will not be populated for that particular test record.

 

For more details refer the "MedDRA Mapping - Export" section.

 

Below is the sample data for <resultstestsprocedures> tag, when Test name doesn’t contain the MedDRA code/decode.

 

<resultstestsprocedures>TESTNAME: LAB TEST 5 is not a meddra LLT code, TESTDATEFORMAT: 102, TESTDATE: 19960212, TESTRESULT: 234, TESTUNIT: 234, LOWTESTRANGE: 234, HIGHTESTRANGE: 234, MOREINFORMATION: Yes ; TESTNAME: TEST 6, TESTDATEFORMAT: 102, TESTDATE: 19760312, TESTRESULT: 2323 ; LABORATORY DESCRIPTION: SOME TEXT FROM  AER.LABORATORY_DESCRIPTION</resultstestsprocedures>.

 

 

B.3.1a & B.3.1b - Testdateformat & Testdate

B.3.1.1 - Lowtestrange

B.3.1c - Testname

B.3.1.2 - Hightestrange

B.3.1d - Testresult

B.3.1.3 - Moreinformation

B.3.1e - Testunit

 

 

Back to ICHICSR Safety Report